Vortex®-90EX Silicon Drift Detector

Why Our Products Are Better

  • Large Active Area
  • High Throughput
  • Reliability

General Description - Vortex-90EX

Vortex-EX silicon drift X-ray detectors feature active areas between 30 mm2 and 80 mm2. Vortex-90EX detectors are produced from high purity silicon using state-of-the-art CMOS production technology. They feature excellent energy resolution (<130 eV FWHM at Mn Kα is typical) and a high count rate capability. At a very short peaking time of 0.1 µs, an output count rate of 900 kcps is achieved. A unique feature of these detectors is their ability to process high count rates with very small loss in energy resolution and minimal peak shift with count rate.

Typical Applications

  • X-ray fluorescence (XRF) spectroscopy both bulk and micro-fluorescence
  • Micro XRF (additional sizes available in near future)
  • X-ray diffraction (XRD)
  • Partical Induced X-ray Emission (PIXE)
  • Total Reflection X-ray Fluorescence (TXRF)
  • Synchrotron radiation applications
  • Process control

The Vortex-90EX is operated at near room temperature and cooled by a thermoelectric cooler (TEC) and can be cycled as frequently as needed without any degradation in detector performance. Cool down times are typically less than 2 minutes.

The Vortex-90EX X-ray spectroscopy systems include the detector unit and control box which includes power supplies for the detector, TEC and an optional digital pulse processor (DPP) with PI-SPEC Software.

The complete detector also contains a charge-sensitive preamplifier and temperature stabilization system, which eliminates concerns of varying ambient temperature.

Features

  • Extended probe (90 mm)
  • Available in 30, 40, 50, 65, 70, 80 mm2
  • Available in thickness of 0.5, 1, and 2 mm
  • Superb energy resolution
  • Detector temperature stabilization
  • Additional sizes are available under special contracts
  • Small and compact package for minimum vibration
  • Digital pulse processor (DPP) with PI-SPEC Software
  • RoHS Compliant
  • US Patent Numbers: 6,455,858 and 7,129,501 B2

Specifications

Detector Material – Silicon Active Area – 30-80 mm2 – Thickness – 0.5, 1, and 2 mm
Window Material – Beryllium Thickness – 12.5 and 25 µm (alternatives available)
Energy Resolution (FWHM) @ 5.9 keV @ 1.0 µs Peaking Time 124 eV - 138 eV
@ 0.5 µs Peaking Time 130 eV - 139 eV
@ 0.25 µs Peaking Time 135 eV - 148 eV
@ 0.1 µs Peaking Time 145 eV - 180 eV
Preamplifier Type – Charge sensitive, 1.5 mV/keV Signal polarity – Positive Reset – Electrical, <1 µs duration Rise time – <100 ns
Cooling Thermoelectric
Power Consumption Nominal voltage – 110/230 V (switchable)
Power supply and detector – 40 W Maximum
Physical Specifications Detector package weight – 950 g Length – 241 mm (90 mm probe)
Height×Width – 64 mm×64 mm Cable Standard Length – 3 m
Digital Pulse Processor (DPP)
Digital Controls Gain – 16-Bit DAC Peaking Time – 0.25 - 16 µs Preset Time – Up to 1717s
Data Output Spectrum Size – 1024, 2048 or 4096 channels Channel Size – 10, 20 or 40 eV
Integral Non-linearity 0.1% of full-scale output
Deadtime Correction Better than ± 0.5% accuracy from 0 to 120,000 cps at 4 µs peaking time
Software PI-SPEC software* – Allows user to acquire, manipulate spectra. Pentium III or later with at least 64 MB memory and 30 MB available disk space.
VTXDLL package
* – Dynamic-Link Library to facilitate host software communication with the DPP. Pentium III or later with at least 64 MB memory and 30 MB available disk space.

* Requires a standard USB2.0 port

Vortex CUBE Count Rate; XIA Mercury DPP
Vtx QE

Dimensional Drawing

Contact Us