Skip to main content

Hitachi High-Tech
  1. Home
  2. Knowledge
  3. Application Note
  4. Application Notes: Analytical Systems
  5. Application Notes: Potentiometric Titrators

Application Notes: Potentiometric Titrators

We introduce you to plenty of data on analytical methods and their results using our Potentiometric Titrator.

If you have any questions, please contact us by e-mail (Inquiry Form).

Metal

NO. Title
ME09 Quantification of lead ion (Pb2+)
  • Model: COM-1700/1750, COM-1600
ME08 Quantification of lanthanum (La3+)
  • Model: COM-1700/1750, COM-1600
ME07 Quantification of manganese ion (Mn2+)
  • Model: COM-1700/1750, COM-1600
ME06 Quantification of ferrous ion (Fe2+) and ferric ion (Fe3+) in steel plate washing solution
  • Model: COM-1700/1750, COM-1600
ME05 Quantification of ferric ion (Fe3+) when chromic anhydride is contained
  • Model: COM-1700/1750, COM-1600
ME04 Quantification of Ni2+ in mixed solution of Ni2+ and Cu2+
  • Model: COM-1700/1750, COM-1600
ME03 Quantification of fluorine, bromine and chlorine in solder flux
  • Model: COM-1700/1750, COM-1600
ME02 Quantification of trace chlorine ion (Cl-) in copper sulfate solution
  • Model: COM-1700/1750, COM-1600
ME01 Quantification of zinc ion (Zn2+)
  • Model: COM-1700/1750, COM-1600

Food and Beverage

NO. Title
FB08 Measurement of saponification value in edible oil
  • Model: COM-1700/1750, COM-1600
FB07 Measurement of iodine number in edible oil
  • Model: COM-1700/1750, COM-1600
FB06 Measurement of acid value of edible oil
  • Model: COM-1700/1750, COM-1600
FB05 Successive measurement of amino nitrogen and acid (citric acid) in grapefruit juice
  • Model: COM-1700/1750, COM-1600
FB04 Successive measurement of citric acid and vitamin C in refreshing drinks
  • Model: COM-1700/1750, COM-1600
FB03 Titration of citric acid in plum (Japanese apricot) juice
  • Model: COM-1700/1750, COM-1600
FB02 Successive titration of acid and salt in dressings
  • Model: COM-1700/1750, COM-1600
FB01 Measurement of salt in soy sauce
  • Model: COM-1700/1750, COM-1600

Pharmaceuticals

NO. Title
PH18 Measurement of pKa for medical products
  • Model: COM-1700/1750, COM-1600
PH17 Quantification of chlorine in bethanechol chloride
  • Model: COM-1700/1750, COM-1600
PH16 Quantification of iothalamic acid by precipitation titration
  • Model: COM-1700/1750, COM-1600
PH15 Quantification of sodium chloride in peritoneal dialytic fluid
  • Model: COM-1700/1750, COM-1600
PH14 Quantification of sodium edentate (EDTA・2Na) in preparations
  • Model: COM-1700/1750, COM-1600
PH13 Quantification of calcium and magnesium in dialytic fluid and transfusion
  • Model: COM-1700/1750, COM-1600
PH12 Measurement of sulfamethizole purity by diazotization titration
  • Model: COM-1700/1750, COM-1600
PH11 Measurement of sodium sulfisozole purity by diazotization titration
  • Model: COM-1700/1750, COM-1600
PH10 Measurement of 3-amino-N-methylbenzamid (AMB) purity by diazotization titration
  • Model: COM-1700/1750, COM-1600
PH09 Evaluation of titer of sodium nitrite titrant with sulfamic acid
  • Model: COM-1700/1750, COM-1600
PH08 Measurement of pantethine purity
  • Model: COM-1700/1750, COM-1600
PH07 Quantification of iodine in mouth wash
  • Model: COM-1700/1750, COM-1600
PH06 Measurement of cetraxate hydrochloride purity
  • Model: COM-1700/1750, COM-1600
PH05 Measurement of hymecromone purity
  • Model: COM-1700/1750, COM-1600
PH04 Quantification of bethanechol chloride by perchloric acid titration
  • Model: COM-1700/1750, COM-1600
PH03 Quantification of carteolol hydrochloride with perchloric acid titration
  • Model: COM-1700/1750, COM-1600
PH02 Quantification of sodium acetate by erchloric acid titration
  • Model: COM-1700/1750, COM-1600
PH01 Quantification of methylbenactyzium bromide by perchloric acid titration
  • Model: COM-1700/1750, COM-1600

Environmental

NO. Title
EN05 Measurement of alkalinity of mineral water
  • Model: COM-1700/1750, COM-1600
EN04 Measurement of residual chlorine in running water
  • Model: COM-1700/1750, COM-1600
EN03 Titration of calcium hardness in drinking water
  • Model: COM-1700/1750, COM-1600
EN02 Measurement of total hardness of drinking water
  • Model: COM-1700/1750, COM-1600
EN01 Quantification of chlorine ion in drinking water
  • Model: COM-1700/1750, COM-1600

Plating

NO. Title
PL08 Quantification of hydrogen peroxide and sulfuric acid in etching solution
  • Model: COM-1700/1750, COM-1600
PL07 Quantification of zinc (Zn2+) in zinc plating solution
  • Model: COM-1700/1750, COM-1600
PL06 Quantification of tin (Sn2+) in solder plating solution
  • Model: COM-1700/1750, COM-1600
PL05 Quantification of lead in solder plating solution
  • Model: COM-1700/1750, COM-1600
PL04 Quantification of chromic anhydride (CrO3) and trivalent chromium (Cr3+) in chrome plating solution
  • Model: COM-1700/1750, COM-1600
PL03 Quantification of nickel chloride (NiCl2) in nickel plating solution
  • Model: COM-1700/1750, COM-1600
PL02 Quantification of copper and sodium cyanide in copper cyanide plating solution
  • Model: COM-1700/1750, COM-1600
PL01 Quantification of silver and free cyanides in silver cyanide plating solution
  • Model: COM-1700/1750, COM-1600

Electronics

NO. Title
EL08 Quantification of remover in photoresist remover solution
  • Model: COM-1700/1750, COM-1600
EL07 Quantification of free acid in lead frame treatment solution for IC
  • Model: COM-1700/1750, COM-1600
EL06 Quantification of oxalic acid in lead frame treatment solution for IC
  • Model: COM-1700/1750, COM-1600
EL05 Quantification of H2O2 in silicon wafer abrasive solution
  • Model: COM-1700/1750, COM-1600
EL04 Measurement of acid value in transformer oil
  • Model: COM-1700/1750, COM-1600
EL03 Quantification of trace chlorine ion in freezer lubricant
  • Model: COM-1700/1750, COM-1600
EL02 Quantification of trace chlorine ion in SiO2 (silicon dioxide)
  • Model: COM-1700/1750, COM-1600
EL01 Quantification of trace chlorine ion in IC molding resin
  • Model: COM-1700/1750, COM-1600

Paper and Pulp

NO. Title
PA10 Quantification of chlorine dioxide in pulp bleaching solution
  • Model: COM-1700/1750, COM-1600
PA09 Quantification of NaOH, Na2S and Na2CO3 in pulp cooking solution
  • Model: COM-1700/1750, COM-1600
PA08 Quantification of sodium oxide (Na2S) and silicic acid (SiO2) in sodium silicate
  • Model: COM-1700/1750, COM-1600
PA07 Measurement of sodium chlorate (NaClO3) purity
  • Model: COM-1700/1750, COM-1600
PA06 Quantification of sodium chloride in sodium hypochlorite
  • Model: COM-1700/1750, COM-1600
PA05 Quantification of residual alkali in sodium hypochlorite
  • Model: COM-1700/1750, COM-1600
PA04 Quantification of available chlorine in sodium hypochlorite
  • Model: COM-1700/1750, COM-1600
PA03 Quantification of trace chlorine ion in sodium hydroxide
  • Model: COM-1700/1750, COM-1600
PA02 Fractionation quantification of mixture of sodium hydroxide (NaOH) and sodium carbonate (Na2CO3)
  • Model: COM-1700/1750, COM-1600
PA01 Measurement of sodium hydroxide purity
  • Model: COM-1700/1750, COM-1600

Inorganic Acid

NO. Title
IN09 Successive quantification of cyanide and cyanic acid in metal treatment salt
  • Model: COM-1700/1750, COM-1600
IN08 Quantification of boric acid in plating solution
  • Model: COM-1700/1750, COM-1600
IN07 Fractionation quantification of mixture of 3 components; nitric acid, hydrofluoric acid and acetic acid
  • Model: COM-1700/1750, COM-1600
IN06 Fractionation quantification of nitric acid andacetic acid
  • Model: COM-1700/1750, COM-1600
IN05 Fractionation quantification of hydrochloric acid and sulfuric acid
  • Model: COM-1700/1750, COM-1600
IN04 Fractionation quantification of nitric acid and hydrofluoric acid
  • Model: COM-1700/1750, COM-1600
IN03 Fractionation quantification of hydrochloric acid and hydrofluoric acid
  • Model: COM-1700/1750, COM-1600
IN02 Measurement of phosphoric acid purity
  • Model: COM-1700/1750, COM-1600
IN01 Measurement of sulfuric acid purity
  • Model: COM-1700/1750, COM-1600

Organic Acid

NO. Title
OR09 Fractionation quantification of peracetic acid and hydrogen peroxide
  • Model: COM-1700/1750, COM-1600
OR08 Fractionation quantification of ascorbic acid and sodium ascorbate
  • Model: COM-1700/1750, COM-1600
OR07 Fractionation quantification of acetic acid and ammonium acetate
  • Model: COM-1700/1750, COM-1600
OR06 Quantification of phthalic acid
  • Model: COM-1700/1750, COM-1600
OR05 Quantification of oxalic acid
  • Model: COM-1700/1750, COM-1600
OR04 Quantification of lactic acid
  • Model: COM-1700/1750, COM-1600
OR03 Quantification of citric acid
  • Model: COM-1700/1750, COM-1600
OR02 Quantification of formic acid
  • Model: COM-1700/1750, COM-1600
OR01 Measurement of acrylic acid purity
  • Model: COM-1700/1750, COM-1600

Petroleum Products

NO. Title
PE10 Measurement of bromine index in aromatic compounds
  • Model: COM-1700/1750, COM-1600
PE09 Measurement of bromine value in nonene
  • Model: COM-1700/1750, COM-1600
PE08 Quantification of chlorides in freezer oils
  • Model: COM-1700/1750, COM-1600
PE07 Measurement of reserve alkalinity in antifreeze
  • Model: COM-1700/1750, COM-1600
PE06 Measurement of total acid value in turbine oils
  • Model: COM-1700/1750, COM-1600
PE05 Measurement of total acid value in freezer oils
  • Model: COM-1700/1750, COM-1600
PE04 Measurement of total acid value in transformer oils
  • Model: COM-1700/1750, COM-1600
PE03 Measurement of total base value in lubricants (perchloric acid method)
  • Model: COM-1700/1750, COM-1600
PE02 Measurement of total base value in lubricants(hydrochloric acid method)
  • Model: COM-1700/1750, COM-1600
PE01 Measurement of total acid value in lubricants
  • Model: COM-1700/1750, COM-1600

Plating Solution

NO. Title
PLS01 Plating Solution application data for COM series
  • Model: COM-1700/1750, COM-1600

Products & Services

Contact Us