HINL100A/200A Series Signal Converters

The HINL 100A/200A Series signal converters receives process signals such as flow rate, pressure, temperature, etc. and converts isolated signals to standardized signals. These highly-reliable signal converters; which have a rich product lineup, can be used in a wide variety of applications.

Features

  • Removable plug-in structure
  • Does not use an aluminum electrolytic capacitors that has components with limited lifespan.

100A Series

Isolated 1 output (4 - 20mA DC or 1 - 5V DC output, please specify when ordering)

200A Series

Since it is an isolated 2 output (4 - 20mA DC or 1 - 5V DC, please specify when ordering), it can be used independently or monitoring and control.

Lineup

HINL100A/200A Series Signal Converters Product Lineup
ModelProduct name
100TCA/200TCA Thermocouple temperature converter
100TRA/200TRA Resistance temperature detector (RTD) temperature converter
100MVA/200MVA mV converter
100PRA/200PRA Potentiometer converter
100DLA/200DLA Distributor
100DRA/200DRA Distributor (with square root extractor)
100ICA/200ICA Isolator
100VIA/200VIA Voltage-current converter

Specification

HINL100A Series Signal Converters Product Specifications-1
Model100TCA100TRA100MVA100PRA
Input signal JIS Standards Thermocouple
R,K,E,J,T,S,B,N
JIS Standards Resistance temperature detectors (RTD)
Pt100
mV,V,mA Potentiometer
130-2000Ω
Output signal Isolation 1 output: Output 1- 5V DC or 4 - 20mA DC (please specify when ordering)
Allowable load
resistance of output signal
1 - 5V DC output: more than 2kΩ
4 - 20mA DC output: less than 750Ω
Conversion accuracy ±0.4%FS(Note 1) ±0.25%FS(Note 1) ±0.2%FS(Note 1) ±0.25%FS
Power supply voltage 85-132V AC 50/60Hz or 24V DC (please specify when ordering)
Power consumption (VA)
(at 100V AC drive)
2.8 2.8 2.8 2.9
Isolation Interconnection present among Input - Output - Power supply
Withstand voltage Between the ground terminal and power supply terminal: 2000V AC, 1 minute
Interconnection among Input / Output / Power supply: 2000V AC, 1 minute
Insulation resistance Between each terminal and ground terminal: 100MΩ / 500V DC
Installation method DIN rail or wall mounting compatible
Weight Equipment: Approx. 220g Socket: Approx. 60g
Function changeover switch - - - -
HINL 100A Series Signal Converters Product Specification-2
Model100DLA100DRA100ICA100VIA
Input signal Two-wire system transmitter (nominal 24V DC) Output 1-5V DC or
4-20mA DC (please
specify when ordering.)
Various voltage and current signals
Output signal Isolation 1 output: Output 1-5V DC or 4-20 mA DC (please specify when ordering.)
Allowable load resistance of output signal 1-5V DC output: above 2kΩ
4-20mA DC output: below 750Ω
Conversion accuracy ±0.2%FS ±0.3%FS ±0.2%FS ±0.2%FS(Note 1)
Power supply voltage 85-132V AC 50/60Hz or 24V DC (please specify when ordering.)
Power consumption(VA)
(at 100V AC drive)
3.7 3.7 2.8 2.8
Isolation Interconnection present among Input - Output - Power supply
Withstand voltage Between the ground terminal and power supply terminal: 2000V AC, 1 minute
Interconnection among Input / Output / Power supply: 2000V AC, 1 minute
Insulation resistance Between each terminal and ground terminal: 100MΩ / 500V DC
Installation method DIN rail or wall mounting compatible
Weight Equipment: Approx. 220g Socket: Approx.60g
Function changeover switch Transmitter
power: ON/OFF
Transmitter
power: ON/OFF
- -

Note 1 The accuracy changes depending on the range and the input specifications, please refer to the CS sheet.

HINL 200A Series Signal Converters Product Specification -1
Model200TCA200TRA200MVA200PRA
Input signal JIS Standards Thermocouple
R,K,E,J,T,S,B,N
JIS Standards Resistance temperature detectors (RTD)
Pt100Ω
mV,V,mA Potentiometer
130-2000Ω
Output signal Isolation 2 output: Output 1-5V DC or 4-20mA DC (please specify when ordering)
Allowable load
resistance of output signal
1-5V DC output: above 250kΩ (First output), above 2kΩ (Second output)
4-20mA DC output: below 750Ω (First output) below 350Ω (Second output)
Conversion accuracy ±0.4%FS
(More than 5mV Span)(Note 1)
±0.25%FS(Note 1) ±0.2%FS(Note 1) ±0.25%FS
Power supply voltage 85-132V AC 50/60Hz or 24V DC (please specify when ordering)
Power consumption (VA)
(at 100V AC drive)
3.3 3.3 3.3 3.4
Isolation Interconnection present among Input - First Output - Second output - Power supply
Withstand voltage Between the ground terminal and power supply terminal: 2000V AC, 1 minute
Interconnection among Input / Output / Power supply: 2000V AC, 1 minute
Interconnection among output: 1000V AC, 1 minute
Insulation resistance Between each terminal and ground terminal: 100MΩ / 500V DC
Structure Flat-type plug-in structure (socket: Dedicated 11-pin socket, screw terminal M3)
Installation method DIN rail or wall mounting compatible
Weight Equipment: Approx. 220g Socket: Approx.80g
Function changeover switch - - - -
HINL200A Series Signal Converters Product Specifications-2
Model200DLA200DRA200ICA200VIA
Input signal Two-wire system transmitter (nominal DC24V) Output 1 - 5V DC or 4 -
20mA DC (please
specify when ordering)
Various voltage and current signals
Output signal Isolation 2 output: Output 1 - 5V DC or 4 - 20mA DC(please specify when ordering)
Allowable load
resistance of output signal
1 - 5V DC output: above 250kΩ (First output), above 2kΩ (Second output)
4 - 20mA DC output: below 750Ω (First output) below 350 (Second output)
Conversion accuracy ±0.2%FS ±0.3%FS ±0.2%FS ±0.2%FS(Note 1)
Power supply voltage 85 - 132V DC 50/60Hz or 24V DC (please specify when ordering)
Power consumption (VA)
(at 100V AC drive)
4.2 4.2 3.3 3.3
Isolation Interconnection present among Input - First Output - Second output - Power supply
Withstand voltage Between the ground terminal and power supply terminal: 2000V AC, 1 minute
Interconnection among Input / Output / Power supply: 2000V AC, 1 minute
Interconnection among output: 1000V AC, 1 minute
Insulation resistance Between each terminal and ground terminal: 100MΩ / 500V DC
Installation method DIN rail or wall mounting compatible
Weight Equipment: Approx. 220g Socket: Approx. 80g
Function changeover switch Transmitter power
ON/OFF
Transmitter power
ON/OFF
- -

Note 1 The accuracy changes depending on the range and the input specifications, please refer to the CS sheet.