HINL150A/250A Series Signal Converters

HINL150A/250A Series Signal Converters

The HINL150A / 250A Series signal converters come with standard functions such as burnout functions, square root extraction operation, and other functions while having a compact body with a width of 26mm (about half of the HINL200 series).

Features

  • Electrical current with isolation, 2 output is possible (4 - 20mA DC × 2)
  • Can be installed by attaching
    Spacer is not needed, high-density mounting is possible.

Lineup

HINL 150A/250A Series Signal Converters Product Lineup
ModelProduct name
150TCA/250TCA Thermocouple temperature converter
150TRA/250TRA Resistance temperature detector (RTD) temperature converter
150MVA/250MVA mV converter
150PRA/250PRA Potentiometer converter
150DLA/250DLA Distributor
150DRA/250DRA Distributor (with square root extractor)
150ICA/250ICA Isolator
150VIA/250VIA Voltage-current converter

Specification

HINL 150 A Series Signal Converters Product Specification-1
Model150TCA150TRA150MVA150PRA
Input signal JIS Standards
Thermocouple
R,K,E,J
T,S,B,N
JIS Standards
Resistance temperature detectors (RTD)
Pt100
mV,V,mA Potentiometer
130-2000Ω
Output signal Isolation 1 output: Output 1-5V DC or 4-20mA DC (please specify when ordering)
Allowable load
resistance of output signal
1-5V DC output: above 2kΩ
4-20mA DC output: below 750Ω
Conversion accuracy ±0.4%FS(Note 1)
(More than 5mV span)
Zero transition less than 50%
±0.25%FS
(More than 50°C span)
(Note 1)
±0.2%FS(Note 1) ±0.25%FS
Power supply voltage 85-132V AC 50/60Hz or 24V DC (please specify when ordering)
Power consumption(VA)
(at 100V AC drive)
4.2 4.2 3.3 3.3
Isolation Interconnection present among Input - First Output - Second output - Power supply
Withstand voltage Between the ground terminal and power supply terminal: 2000V AC, 1 minute
Interconnection among Input / Output / Power supply: 2000V AC, 1 minute
Interconnection among output: 1000V AC, 1 minute
Insulation resistance Between each terminal and ground terminal: 100MΩ / 500V DC
Structure Flat-type plug-in structure (socket: Dedicated 11-pin socket, screw terminal M3)
Installation method DIN rail or wall mounting compatible
Weight Equipment: Approx. 150g Socket: Approx.30g
Function changeover switch Transmitter power: can be changed by the ON / OFF (short metal fixture) Transmitter power: can be changed by the ON / OFF (short metal fixture) - -

Note 1 The accuracy changes depending on the range and the input specifications, please refer to the CS sheet.

HINL 150 A Series Signal Converters Product Specification-2
Model150DLA150DRA150ICA150VIA
Input signal Two-wire system transmitter
(nominal 24V DC)
Output DC1-5V or 4-20mA DC (please specify when ordering) Various voltage and current signals
Output signal Isolation 1 output: Output 1-5V DC or 4-20mA DC (please specify when ordering)
Allowable load
resistance of output signal
1-5V DC output: above 2kΩ
4-20mA DC output: below 750Ω
Conversion accuracy ±0.2%FS ±0.3%FS
(Output 0% and
10-100%)(Note 1)
±0.2%FS ±0.2%FS
(More than 5mV span)
Zero transition less than 50%
Power supply voltage 85-132V AC 50/60Hz or 24V DC (please specify when ordering)
Power consumption(VA)
(at 100V AC drive)
3.7 3.7 2.8 2.8
Isolation Interconnection present among Input - First Output - Second output - Power supply
Withstand voltage Between the ground terminal and power supply terminal: 2000V AC, 1 minute
Interconnection among Input / Output / Power supply: 2000V AC, 1 minute
Insulation resistance Between each terminal and ground terminal: 100MΩ / 500V DC
Structure Flat-type plug-in structure (socket: Dedicated 11-pin socket, screw terminal M3)
Installation method DIN rail or wall mounting compatible
Weight Equipment: Approx. 150g Socket: Approx.30g
Function changeover switch Transmitter power : can be changed by the ON / OFF (short metal fixture) Transmitter power : can be changed by the ON / OFF (short metal fixture) - -

Note 1 The accuracy changes depending on the range and the input specifications, please refer to the CS sheet.

HINL 250 A Series Signal Converters Product Specification-1
Model250TCA250TRA250MVA250PRA
Input signal JIS Standards
Thermocouple
R,K,E,J,
T,S,B,N
JIS Standards
Resistance temperature detectors (RTD)
Pt100
mV,V,mA Potentiometer
130-2000Ω
Output signal Isolation 2 output: Output 1-5V DC or 4-20mA DC (please specify when ordering)
Allowable load
resistance of output signal
1-5V DC output: above 2kΩ (First and second output have both the same specifications)
4-20mA DC output: below 750Ω (First output) below 350 (Second output)
Conversion accuracy ±0.4%FS(Note 1)
(More than 5mV span)
Zero transition less than 50%
±0.25%FS
(More than 50°C span)
(Note 1)
±0.2%FS(Note 1) ±0.25%FS
Power supply voltage 85-132V AC 50/60Hz or 24V DC (please specify when ordering)
Power consumption(VA)
(at 100V AC drive)
3.3 3.3 3.3 3.4
Isolation Interconnection present among Input - First Output - Second output - Power supply
Withstand voltage Between the ground terminal and power supply terminal: 2000V AC, 1 minute
Interconnection among Input / Output / Power supply: 2000V AC, 1 minute
Interconnection among output: 1000V AC, 1 minute
Insulation resistance Between each terminal and ground terminal: 100MΩ / 500V DC
Structure Flat-type plug-in structure (socket: Dedicated 11-pin socket, screw terminal M3)
Installation method DIN rail or wall mounting compatible
Weight Equipment: Approx. 150g Socket: Approx.30g
Function changeover switch - - - -

Note 1 The accuracy changes depending on the range and the input specifications, please refer to the CS sheet.

HINL 250 A Series Signal Converters Product Specification-2
Model250DLA250DRA250ICA250VIA
Input signal JIS Standards
Thermocouple
R,K,E,J,T,S,B,N
JIS Standards
Resistance temperature detectors (RTD)
Pt100
mV,V,mA Potentiometer 130-2000Ω
Output signal Isolation 2 output: Output 1-5V DC or 4-20mA DC (please specify when ordering)
Allowable load
resistance of output signal
1-5V DC output: above 2kΩ (First and second output have both the same specifications)
4-20mA DC output: below 750Ω (First output) below 350 (Second output)
Conversion accuracy ±0.2%FS ±0.3%FS
(Output 0% and
10-100%)(Note 1)
±0.2%FS ±0.2%FS
(More than 5mV span)
Zero transition less than 50%
Power supply voltage 85-132V AC 50/60Hz or 24V DC (please specify when ordering)
Power consumption(VA)
(at 100V AC drive)
4.2 4.2 3.3 3.3
Isolation Interconnection present among Input - First Output - Second output - Power supply
Withstand voltage Between the ground terminal and power supply terminal: 2000V AC, 1 minute
Interconnection among Input / Output / Power supply: 2000V AC, 1 minute
Interconnection among output: 1000V AC, 1 minute
Insulation resistance Between each terminal and ground terminal: 100MΩ / 500V DC
Structure Flat-type plug-in structure (socket: Dedicated 11-pin socket, screw terminal M3)
Installation method DIN rail or wall mounting compatible
Weight Equipment: Approx.150g Socket: Approx.30g
Function changeover switch Transmitter power : can be changed by the ON / OFF (short metal fixture) Transmitter power : can be changed by the ON / OFF (short metal fixture) - -

Note 1 The accuracy changes depending on the range and the input specifications, please refer to the CS sheet.